NSN 5930-01-089-9840

Sensitive Switch
DEMIL
Shelf Life
UOM
NIIN
Demil:
NO
Shelf Life:
N/A
UOM:
--
NIIN:
010899840

Pricing & Availability Check

Submit this form for stock availability and pricing.
Part Number:
Quantity:
Email Address:
Phone Number:
Your Name:
Company:

Inventory

 

This product may be available in the following quantities and conditions.

  • NE: 1
  • NS: 1

Please note that inventory for this NSN was updated 08/14/2025 and may have changed since then. Request a quote for up to date pricing and availability.

Product Definition Definition of approved item name (AIN): "SWITCH,SENSITIVE"

A switch with a quick-acting mechanism actuated by a highly delicate tactile contact. Includes membrane switch. excludes switch, flexible; switch, pressure; and switch, thermostatic.

5930-01-089-9840 Spec. NSN part characteristics

MRC
Name
Detail
MRC:
AAQL
Body Style
Hole mounted
MRC:
ABKQ
Center To Center Distance Between Mounting Facilities Parallel To Length
0.375 inches
MRC:
ADAQ
Body Length
0.876 inches
MRC:
ADAT
Body Width
0.346 inches
MRC:
ADAU
Body Height
0.390 inches
MRC:
AEBV
Unthreaded Mounting Hole Diameter
Between 0.087 inches and 0.090 inches
MRC:
AFUQ
Actuator Style
Round
MRC:
AFUR
Actuator Diameter
0.078 inches
MRC:
AFUU
Actuator Free Position Height
0.475 inches
MRC:
AFXE
Maximum Voltage Rating In Volts
250.0 ac and 30.0 dc
MRC:
AKNA
Inclosure Type
Fully enclosed
MRC:
CBBL
Features Provided
Actuator seal
MRC:
CRLD
Nonpile-up Contact Arrangement
1 pole, double throw, one position momentary single switch unit
MRC:
CRRM
Switch Release Force
4.0 ounces
MRC:
CSJN
Switch Actuating Force
Between 5.0 ounces and 17.0 ounces
MRC:
CXQQ
Actuator Movement
Between 0.050 pretravel inches and 0.003 overtravel inches and 0.004 differential inches
MRC:
CXQR
Contact Load Current Rating At Maximum Rated Voltage
5.000 amperes resistive dc and 3.000 amperes inductive dc and 5.000 amperes resistive ac
MRC:
FEAT
Special Features
Wire leads 36.000 in. Min. L, leads marked with circuit and awg, closed 20, open 20 and common 20
MRC:
TTQY
Terminal Type And Quantity
3 wire lead

Cross Reference Parts Part numbers that meet the specification outlined on this page and set by the OEM

Part Number
Cage
RNCC
RNVC
DAC
RNAAC
Status
MSDS
SADC
Part Number:
5SE218-3
Cage Code:
91929
RNCC:
3
RNVC:
2
DAC:
2
RNAAC:
9Z
Status:
A
MSDS:
SADC:
Part Number:
5SE218-3
Cage Code:
F1907
RNCC:
5
RNVC:
2
DAC:
4
RNAAC:
ZF
Status:
A
MSDS:
SADC:
Part Number:
5SE218-3
Cage Code:
R1120
RNCC:
5
RNVC:
2
DAC:
6
RNAAC:
ZG
Status:
A
MSDS:
SADC:
Part Number:
5SE218-3
Cage Code:
R1120
RNCC:
5
RNVC:
2
DAC:
6
RNAAC:
ZG
Status:
A
MSDS:
SADC:
Part Number:
5SE218-3
Cage Code:
R1120
RNCC:
5
RNVC:
2
DAC:
6
RNAAC:
ZG
Status:
A
MSDS:
SADC:
Part Number:
5SE218-3
Cage Code:
91929
RNCC:
3
RNVC:
2
DAC:
2
RNAAC:
9Z
Status:
A
MSDS:
SADC:
Part Number:
5SE218-3
Cage Code:
F1907
RNCC:
5
RNVC:
2
DAC:
4
RNAAC:
ZF
Status:
A
MSDS:
SADC:
Part Number:
5SE218-3
Cage Code:
R1120
RNCC:
5
RNVC:
2
DAC:
6
RNAAC:
ZG
Status:
A
MSDS:
SADC:
Part Number:
5SE218-3
Cage Code:
91929
RNCC:
3
RNVC:
2
DAC:
2
RNAAC:
9Z
Status:
A
MSDS:
SADC:
Part Number:
5SE218-3
Cage Code:
F1907
RNCC:
5
RNVC:
2
DAC:
4
RNAAC:
ZF
Status:
A
MSDS:
SADC:
Part Number:
5SE218-3
Cage Code:
R1120
RNCC:
5
RNVC:
2
DAC:
6
RNAAC:
ZG
Status:
A
MSDS:
SADC:
Part Number:
5SE218-3
Cage Code:
91929
RNCC:
3
RNVC:
2
DAC:
2
RNAAC:
9Z
Status:
A
MSDS:
SADC:
Part Number:
5SE218-3
Cage Code:
F1907
RNCC:
5
RNVC:
2
DAC:
4
RNAAC:
ZF
Status:
A
MSDS:
SADC:
Part Number:
5SE218-3
Cage Code:
R1120
RNCC:
5
RNVC:
2
DAC:
6
RNAAC:
ZG
Status:
A
MSDS:
SADC:
Indicates a design/source control reference item
Inidicates part number has been superseded

Identification Item Identification Guide (IIG) and Item Name Code (INC)

INC
FIIG
Concept No.
App. Key
Cond. Code
Status
INC:
00399
FIIG:
A053A0
Concept No.:
App. Key:
S
Cond. Code:
1
Status:
A

Special material and handling

HMIC
PMIC
ESD
ENAC
ADPE
CRITL
HMIC:
P
PMIC:
U
ESD:
ESD:
ADPE:
CRITL:
X
Hazmat (HMIC) P

Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.

Precious Metals (PMIC) U

Precious metal content is unknown

Criticality X

The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

Import and Export

Schedule B
NAIC
End Use
SITC
USDA
HITECH
Schedule B:
8536509050
NAICS:
335931
End Use Class:
20005
SITC:
77255
USDA:
1
HITECH:
0

Schedule B Codes Definitions:

Schedule B 8536509050

Switches, Slide, For A Voltage Not Exceeding 1, 000 V

End Use Code 20005

Electric Apparatus

Standard Intl. Trade Class (SITC) 77255

Switches For Electrical Apparatus, N.e.s., For Voltages Not Exceeding 1, 000 Volts

National motor freight and handling

NMFC
Class
UFC
LTL
LCL
WCC
TCC
SHC
ADC
ACC
NMFC:
061300
NMF Description:
Circuit Breaker/switch Noi
UFC:
34410
LTL:
77.5
LCL:
77.5
WCC:
658
TCC:
Z
SHC:
9
ADC:
A
ACC:
H

Freight Codes Definitions:

Cargo Type (TCC) Z

No special type of cargo code applicable.

Water Commodity (WCC) 658

Electrical appliances, small.

Air Commodity (ACC) H

Instruments/equipment/supplies for radio, communications, electrical, laboratory, etc. (includes signal corps).

Air Dimensions (ADC) A

Shipment is not a consolidation and does not exceed 84 inches in any dimension.

Air Special Handling (SHC) 9

Other or no special handling required (sh)